<?xml version="1.0" encoding="utf-8"?>
|
|
<ids xmlns:xs="http://www.w3.org/2001/XMLSchema"
|
|
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
|
|
xmlns="http://standards.buildingsmart.org/IDS">
|
|
<info>
|
|
<title>CI Project Checks</title>
|
|
<description>Checks derived from BoQ, QTO, and scheduling requirements for this project.
|
|
QTO checks: verifies ifc_quantify has been run and quantities are present for all BoQ cost
|
|
item links. Scheduling checks: verifies elements are named so schedule task descriptions and
|
|
BoQ Quantities column are meaningful. BoQ property checks: verifies structural and energy
|
|
properties needed for cost planning and energy analysis are present.</description>
|
|
<date>2026-02-24</date>
|
|
<purpose>CI validation — run on every commit to main</purpose>
|
|
</info>
|
|
<specifications>
|
|
|
|
<!-- ================================================================
|
|
QTO CHECKS
|
|
The BoQ uses parametric quantity links (assign_cost_item_quantity)
|
|
that reference named quantities on elements. If ifc_quantify has
|
|
not been run (or its output was not saved), these links produce
|
|
zero quantities and all BoQ line-item totals collapse to zero.
|
|
================================================================ -->
|
|
|
|
<specification name="(QTO-1) Wall net volumes computed"
|
|
description="Qto_WallBaseQuantities.NetVolume must be present on all IfcWall instances. This quantity is the basis for the BoQ 'Exterior Walls' cost item. Run ifc_quantify('IFC4QtoBaseQuantities') and save before committing."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<entity>
|
|
<name><simpleValue>IFCWALL</simpleValue></name>
|
|
</entity>
|
|
</applicability>
|
|
<requirements>
|
|
<property>
|
|
<propertySet><simpleValue>Qto_WallBaseQuantities</simpleValue></propertySet>
|
|
<baseName><simpleValue>NetVolume</simpleValue></baseName>
|
|
</property>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(QTO-2) Slab net volumes computed"
|
|
description="Qto_SlabBaseQuantities.NetVolume must be present on all IfcSlab instances. This quantity is the basis for the BoQ 'Floor Slab' cost item."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<entity>
|
|
<name><simpleValue>IFCSLAB</simpleValue></name>
|
|
</entity>
|
|
</applicability>
|
|
<requirements>
|
|
<property>
|
|
<propertySet><simpleValue>Qto_SlabBaseQuantities</simpleValue></propertySet>
|
|
<baseName><simpleValue>NetVolume</simpleValue></baseName>
|
|
</property>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(QTO-3) Footing net volumes computed"
|
|
description="Qto_FootingBaseQuantities.NetVolume must be present on all IfcFooting instances. This quantity is the basis for the BoQ 'Ground Beams' cost item."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<entity>
|
|
<name><simpleValue>IFCFOOTING</simpleValue></name>
|
|
</entity>
|
|
</applicability>
|
|
<requirements>
|
|
<property>
|
|
<propertySet><simpleValue>Qto_FootingBaseQuantities</simpleValue></propertySet>
|
|
<baseName><simpleValue>NetVolume</simpleValue></baseName>
|
|
</property>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(QTO-4) Roof gross areas computed"
|
|
description="Qto_RoofBaseQuantities.GrossArea must be present on all IfcRoof instances. This quantity is the basis for the BoQ 'Pitched Roof Structure' cost item."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<entity>
|
|
<name><simpleValue>IFCROOF</simpleValue></name>
|
|
</entity>
|
|
</applicability>
|
|
<requirements>
|
|
<property>
|
|
<propertySet><simpleValue>Qto_RoofBaseQuantities</simpleValue></propertySet>
|
|
<baseName><simpleValue>GrossArea</simpleValue></baseName>
|
|
</property>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(QTO-5) Window areas computed"
|
|
description="Qto_WindowBaseQuantities.Area must be present on all IfcWindow instances. This quantity is the basis for the BoQ 'Exterior Windows' cost item."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<entity>
|
|
<name><simpleValue>IFCWINDOW</simpleValue></name>
|
|
</entity>
|
|
</applicability>
|
|
<requirements>
|
|
<property>
|
|
<propertySet><simpleValue>Qto_WindowBaseQuantities</simpleValue></propertySet>
|
|
<baseName><simpleValue>Area</simpleValue></baseName>
|
|
</property>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<!-- ================================================================
|
|
SCHEDULING CHECKS
|
|
Construction tasks are assigned to physical elements. Element
|
|
names appear in the schedule task descriptions and in the BoQ
|
|
Quantities column (e.g. "exterior - NetVolume"). Unnamed elements
|
|
produce meaningless schedule and BoQ output.
|
|
================================================================ -->
|
|
|
|
<specification name="(SCHED-1) Walls are named"
|
|
description="All IfcWall instances must have a Name. Wall names appear in the BoQ Quantities column and construction schedule task descriptions. Unnamed walls make the schedule and BoQ unreadable."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<entity>
|
|
<name><simpleValue>IFCWALL</simpleValue></name>
|
|
</entity>
|
|
</applicability>
|
|
<requirements>
|
|
<attribute>
|
|
<name><simpleValue>Name</simpleValue></name>
|
|
<value>
|
|
<xs:restriction base="xs:string">
|
|
<xs:pattern value=".+"/>
|
|
</xs:restriction>
|
|
</value>
|
|
</attribute>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(SCHED-2) Windows are named"
|
|
description="All IfcWindow instances must have a Name. Window names appear in the BoQ Quantities column and construction schedule task descriptions."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<entity>
|
|
<name><simpleValue>IFCWINDOW</simpleValue></name>
|
|
</entity>
|
|
</applicability>
|
|
<requirements>
|
|
<attribute>
|
|
<name><simpleValue>Name</simpleValue></name>
|
|
<value>
|
|
<xs:restriction base="xs:string">
|
|
<xs:pattern value=".+"/>
|
|
</xs:restriction>
|
|
</value>
|
|
</attribute>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(SCHED-3) Footings are named"
|
|
description="All IfcFooting instances must have a Name. Footing names appear in the BoQ Quantities column and construction schedule task descriptions."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<entity>
|
|
<name><simpleValue>IFCFOOTING</simpleValue></name>
|
|
</entity>
|
|
</applicability>
|
|
<requirements>
|
|
<attribute>
|
|
<name><simpleValue>Name</simpleValue></name>
|
|
<value>
|
|
<xs:restriction base="xs:string">
|
|
<xs:pattern value=".+"/>
|
|
</xs:restriction>
|
|
</value>
|
|
</attribute>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<!-- ================================================================
|
|
BOQ PROPERTY CHECKS
|
|
These properties are required for the cost planning and energy
|
|
analysis that underpins the BoQ unit rates. Missing properties
|
|
mean rates cannot be properly justified or audited.
|
|
================================================================ -->
|
|
|
|
<specification name="(BOQ-1) Load-bearing walls have fire rating"
|
|
description="All load-bearing walls must have FireRating in Pset_WallCommon. Fire rating drives the cost of fire protection measures and is a mandatory input for building regulation compliance checks that feed into the BoQ."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<property>
|
|
<propertySet><simpleValue>Pset_WallCommon</simpleValue></propertySet>
|
|
<baseName><simpleValue>LoadBearing</simpleValue></baseName>
|
|
<value><simpleValue>True</simpleValue></value>
|
|
</property>
|
|
</applicability>
|
|
<requirements>
|
|
<property>
|
|
<propertySet><simpleValue>Pset_WallCommon</simpleValue></propertySet>
|
|
<baseName><simpleValue>FireRating</simpleValue></baseName>
|
|
</property>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(BOQ-2) Load-bearing walls have material assigned"
|
|
description="All load-bearing walls must have a material assignment. Without a material (with density), ifc_quantify cannot compute NetWeight. Missing weight quantities cause the structural BoQ section to be incomplete and prevent weight-based cost checking."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<property>
|
|
<propertySet><simpleValue>Pset_WallCommon</simpleValue></propertySet>
|
|
<baseName><simpleValue>LoadBearing</simpleValue></baseName>
|
|
<value><simpleValue>True</simpleValue></value>
|
|
</property>
|
|
</applicability>
|
|
<requirements>
|
|
<material/>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(BOQ-3) External walls have thermal transmittance"
|
|
description="All external walls must have ThermalTransmittance (U-value) in Pset_WallCommon. The U-value is used in energy analysis to justify the insulation specification and unit rate in the BoQ."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<property>
|
|
<propertySet><simpleValue>Pset_WallCommon</simpleValue></propertySet>
|
|
<baseName><simpleValue>IsExternal</simpleValue></baseName>
|
|
<value><simpleValue>True</simpleValue></value>
|
|
</property>
|
|
</applicability>
|
|
<requirements>
|
|
<property>
|
|
<propertySet><simpleValue>Pset_WallCommon</simpleValue></propertySet>
|
|
<baseName><simpleValue>ThermalTransmittance</simpleValue></baseName>
|
|
</property>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(BOQ-4) External windows have thermal transmittance"
|
|
description="All external windows must have ThermalTransmittance (U-value) in Pset_WindowCommon. The U-value drives the glazing specification and unit rate in the BoQ 'Exterior Windows' cost item."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<property>
|
|
<propertySet><simpleValue>Pset_WindowCommon</simpleValue></propertySet>
|
|
<baseName><simpleValue>IsExternal</simpleValue></baseName>
|
|
<value><simpleValue>True</simpleValue></value>
|
|
</property>
|
|
</applicability>
|
|
<requirements>
|
|
<property>
|
|
<propertySet><simpleValue>Pset_WindowCommon</simpleValue></propertySet>
|
|
<baseName><simpleValue>ThermalTransmittance</simpleValue></baseName>
|
|
</property>
|
|
</requirements>
|
|
</specification>
|
|
|
|
<specification name="(BOQ-5) External roofs have thermal transmittance"
|
|
description="All external roofs must have ThermalTransmittance (U-value) in Pset_RoofCommon. The U-value drives the roof insulation specification and unit rate in the BoQ 'Pitched Roof Structure' cost item."
|
|
ifcVersion="IFC4">
|
|
<applicability minOccurs="0">
|
|
<property>
|
|
<propertySet><simpleValue>Pset_RoofCommon</simpleValue></propertySet>
|
|
<baseName><simpleValue>IsExternal</simpleValue></baseName>
|
|
<value><simpleValue>True</simpleValue></value>
|
|
</property>
|
|
</applicability>
|
|
<requirements>
|
|
<property>
|
|
<propertySet><simpleValue>Pset_RoofCommon</simpleValue></propertySet>
|
|
<baseName><simpleValue>ThermalTransmittance</simpleValue></baseName>
|
|
</property>
|
|
</requirements>
|
|
</specification>
|
|
|
|
</specifications>
|
|
</ids>
|